The FDMRN20AV1KU / RR20AV1KU listing brings ducted cooling to rooms where the indoor equipment is concealed above the ceiling. Its catalogue model family, FDMRN20AV1K / RR20AV1K, provides 18,000 Btu/h of nominal T1 cooling with R-410A refrigerant and a rotary compressor. Air is distributed through a designed duct system to suit the space.
Cooling capacity and efficiency
| Store model / outdoor unit | FDMRN20AV1KU / RR20AV1KU |
|---|---|
| Catalogue model family | FDMRN20AV1K / RR20AV1K |
| T1 cooling capacity | 5.28 kW / 18,000 Btu/h |
| T3 cooling capacity | 4.62 kW / 15,750 Btu/h |
| T1 EER | 11.91 (Btu/h)/W |
| T3 EER | 8.73 (Btu/h)/W |
| Power supply | 230 V, 1 phase, 50 Hz |
| Compressor | Rotary |
| Refrigerant / operation | R-410A / cooling only |
T1 test conditions: indoor 27°C dry bulb / 19°C wet bulb; outdoor 35°C dry bulb / 24°C wet bulb. T3: indoor 29°C dry bulb / 19°C wet bulb; outdoor 46°C dry bulb / 24°C wet bulb. All figures are at 50 Hz. The catalogue uses model-family codes without the store’s trailing U suffix; the figures above are from its standard AV1K/AY1K columns, not the separate RE or K9 variants.
Ductwork, dimensions and installation planning
| Rated / maximum ESP at high fan | 40 / 50 Pa |
|---|---|
| Indoor airflow H/M/L | 721 / 618 / 432 CFM |
| Indoor noise H/M/L | 41 / 39 / 36 dB(A) |
| Indoor dimensions H × W × D | 261 × 1137 × 388 mm |
| Outdoor dimensions H × W × D | 753 × 855 × 328 mm |
| Liquid pipe connection | 6.35 mm (1/4 inch) |
| Gas pipe connection | 12.7 mm (1/2 inch) |
| Maximum total / vertical piping | 50 m / 30 m |
| Catalogue operating temperature range | 19–54°C |
Allow for the 261 mm indoor casing height, service access and the pressure loss of the complete duct system. Use the rated 40 Pa and maximum 50 Pa values when checking the installation design. The operating temperature limit is separate from the rated cooling capacity.
Controls and model-specific features
The series brochure describes Turbo, Sleep and Dry modes and illustrates the BRC51A62Y wired controller. Confirm the controller supplied with your order. Auto random restart resumes operation using the previous settings after a power interruption, with staggered restarting across units.
The FDMRN20–50 family includes the catalogue’s double drain-pan arrangement. The matched outdoor model uses a hydrophilic gold-fin coating on its copper-to-aluminium heat exchanger.
Selecting ducted cooling in Dubai
Match the cooling load, available electrical supply, ceiling space and duct resistance before choosing a system. Compare the Daikin FDMRN range or browse all ducted split air conditioners. Download the original catalogue in Technical Downloads for the full model table, or call Coolwell on 800 26659355 for selection assistance.